Description

• Plastic (PPE) fire-resistant enclosure (DIN EN 13501). Brackets for wall-mounted installation supplied as standard.
• Front panel made of plastic resin, integrating covers for filters direct access.
• Round duct connection ports, nominal diameter 150 mm.
• 2 EC (brushless) motors, external rotor, with shaft turning in ball bearings to grant a “maintenance free” functioning, each coupled to a backward curved centrifugal impeller; 2 speeds, independently adjustable at the installation.
• High efficiency counter-flow heat exchanger in PS resin.
• Automatic frost-protection to prevent icing on the heat exchanger.
• Automatic, 100% filtered, mechanic by-pass, granting people comfort in the rooms in mid-season or when the outside temperature does not require the action of the heat exchanger.
• Wired control panel with LCD display, which allows:
• to switch on / off the unit;
• the first set-up;
• to set the speed;
• to set the weekly timer;
• to show time and room temperature;
• to monitor the correct product operation (any faults are shown on the display);
• to show the filters status.
• 2 M5 filters (F7 filter for air supply duct available as optional), easy access for periodic maintenance.
• Condense water tray with discharge pipes.
• Possibility of connection to environmental external sensors (available as optional), for automatic functioning control.
Read full descriptionClose description

Certifications

Energy label Energy label

Technical Data Sheet

  • Filter class
    F5
  • Frequency (Hz)
    50
  • Insulation class
  • IP
    X2
  • Max absorbed current (A)
    1,4
  • Max absorbed power (W)
    165
  • Nominal diameter (mm)
    150
  • Voltage (V)
    230
  • Weight (Kg)
    23
  • Breakout sound power LWA [dB(A)]
    57,3
  • Breakout sound pressure at 3m at Max speed Lp [dB (A)]
    36,8
  • Max airflow (l/s)
    100
  • Max airflow (m³/h)
    350
  • Max pressure (mmH2O)
    90
  • Max pressure (Pa)
    880
  • Max thermal efficiency (%)
    90,5
  • Sound power at exhaust inlet LWA [dB(A)]
    43,6
  • Sound power at supply outlet LWA [dB(A)]
    60,2
  • Sound pressure at 3m at Max speed at extraction side Lp [dB (A)]
    23,1
  • Sound pressure at 3m at Max speed at supply side Lp [dB (A)]
    39,7
  • Size A (mm)
    712
  • Size B (mm)
    845
  • Size C (mm)
    455
  • Size D (mm)
    700
  • Size E (mm)
    215
  • Size F (mm)
    410
  • Size G (mm)
    220
  • Size H (mm)
    Ø 150
quota
Curva_JPG_12106-Curve_per_Catalogo

Accessories

Discover accessories related to the product

C TEMP
C TEMP
Environmental sensor for temperature control.
C SMOKE
C SMOKE
Environmental sensor for air quality.
C HCS
C HCS
Environmental sensor for relative humidity control.
C PIR
C PIR
• Passive infrared sensor.
ELECTRIC HEATER 750
ELECTRIC HEATER 750
FTR G3 198X398X15
FTR G3 198X398X15
FTR M5 198X398X15
FTR M5 198X398X15
ePM10 50% (M5) filter. Dimensions: 198x398x15 mm.
KIT FISSAGGIO A PAVIMENTO AVEL
KIT FISSAGGIO A PAVIMENTO AVEL
FTR F7 198X398X15
FTR F7 198X398X15
CB TOUCH LCD W
CB TOUCH LCD W
Remote control panel with color graphic LCD display that can be combined with VORTICE centralized residential heat recovery units. TECHNICAL FEATURES: • Graphic touch display...
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info