Description

• Material: UV resistant plastic (prevents ageing caused by exposure to sunlight).
• Nominal diameter 120 mm.
• Motor protected against thermal overload, with shaft turning in ball bearings, coupled to screw type thermoplastic impeller with wing profile blades.
• Maximum air flow: 175 m3/h.
• Incorporates electronic presence detector with infrared sensor, and electronic timer designed to shut off the motor automatically after a set interval, selectable during installation in the range 3’-20’ (default setting 3’), after the room has been vacated.
• Non-return damper fitted to outlet port.
• Vortice speed controller.
Read full descriptionClose description

Certifications

  • CE CE
    Download
  • EAC EAC
  • G-Mark G-Mark
  • UKCA UKCA
  • CB TEST CERTIFICATE CB TEST CERTIFICATE
punto_filo_ambiente01

Technical Data Sheet

  • Frequency (Hz)
    50
  • Insulation class
    II°
  • IP
    X4
  • Max absorbed current (A)
    0,12
  • Max absorbed power (W)
    20
  • Max ambient temperature for continuous operation (°C)
    50
  • Nominal diameter (mm)
    120
  • Ø Discharge hole (mm)
    119
  • Voltage (V)
    220-240
  • Weight (Kg)
    0,61
  • Max airflow (l/s)
    49
  • Max airflow (m³/h)
    175
  • Max pressure (mmH2O)
    5
  • Max pressure (Pa)
    49
  • RPM
    2150
  • Sound pressure Lp [dB (A)] at 3 m
    34,4
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption (SEC) class in temperate climate zone
    NA
  • Specific Energy Consumption (SEC) class in temperate climate zone [kWh/m2y]
    -8,8
  • Specific Energy Consumption class SEC in cold climate zone [kWh/m2y]
    -22,1
  • Specific Energy Consumption class SEC in warm climate zone [kWh/m2y]
    -1,1
  • Declared type
    UVR-U: unidirezionale
  • Type of drive
    NA
  • Type of heat recovery system HRS
    assente
  • Thermal efficiency of heat recovery at reference airflow [%]
    NA
  • Max airflow [m3/h]
    173
  • Fan drive electric power input, including any motor control equipment, at maximum flow rate [W]
    21,4
  • Sound power LWA [dB(A)]
    60
  • Reference airflow [m3/s]
    0,0336
  • Reference ? pressure [Pa]
    24
  • SPI [W/(m3/h)]
    0,15111
  • Control factor CTRL
    1
  • Control type
    manuale
  • Max internal leakage rate [%]
    NA
  • Max external leakage rate [%]
    NA
  • Mixing rate
    NA
  • Position and description of visual filter warning
    NA
  • Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/y]
    208
  • AHS temperate annual energy saved [kWh primary energy/y]
    1397
  • AHS cold annual energy saved [kWh primary energy/y]
    2732
  • AHS warm annual energy saved [kWh primary energy/y]
    632
  • Size A (mm)
    179
  • Size B (mm)
    17
  • Size C (mm)
    89
  • Size D (mm)
    119