Description

• Material: UV resistant plastic (prevents ageing caused by exposure to sunlight).
• Nominal diameter 150 mm.
• Motor protected against thermal overload, with shaft turning in ball bearings (LL),coupled to screw type thermoplastic impeller with wing profile blades.
• Maximum air flow: 320 m3/h.
• IMQ SAFETY and IMQ PERFORMANCE certifications
• Vortice speed controllers.
Read full descriptionClose description

Certifications

  • IMQ IMQ
  • CE CE
    Download
  • IMQ Performance IMQ Performance
  • EAC EAC
  • G-Mark G-Mark
  • UKCA UKCA
punto_ghost_ambiente01
punto_ghost_ambiente02
punto_ghost_ambiente03

Technical Data Sheet

  • Frequency (Hz)
    50
  • Insulation class
    II°
  • IP
    X4
  • Max absorbed current (A)
    0,18
  • Max absorbed power (W)
    29
  • Max ambient temperature for continuous operation (°C)
    50
  • Voltage (V)
    220-240
  • Weight (Kg)
    0,80
  • Max airflow (l/s)
    88,9
  • Max airflow (m³/h)
    320
  • Max pressure (mmH2O)
    7,0
  • Max pressure (Pa)
    69
  • RPM
    2200
  • Sound pressure Lp [dB (A)] at 3 m
    48
  • Supplier's name or trade mark
    Vortice
  • Specific Energy Consumption (SEC) class in temperate climate zone
    NA
  • Specific Energy Consumption (SEC) class in temperate climate zone [kWh/m2y]
    -10,0
  • Specific Energy Consumption class SEC in cold climate zone [kWh/m2y]
    -23,4
  • Specific Energy Consumption class SEC in warm climate zone [kWh/m2y]
    -2,4
  • Declared type
    UVR-U: unidirezionale
  • Type of drive
    NA
  • Type of heat recovery system HRS
    assente
  • Thermal efficiency of heat recovery at reference airflow [%]
    NA
  • Max airflow [m3/h]
    311
  • Fan drive electric power input, including any motor control equipment, at maximum flow rate [W]
    25,0
  • Sound power LWA [dB(A)]
    69
  • Reference airflow [m3/s]
    0,0605
  • Reference ? pressure [Pa]
    30
  • SPI [W/(m3/h)]
    0,11484
  • Control factor CTRL
    1
  • Control type
    manuale
  • Max internal leakage rate [%]
    NA
  • Max external leakage rate [%]
    NA
  • Mixing rate
    NA
  • Position and description of visual filter warning
    NA
  • Airflow sensitivity to pressure variations at + 20 Pa and – 20 Pa
    NA
  • Indoor/outdoor air tightness [m3/h]
    NA
  • Annual electricity consumption (AEC) [kWh electricity/y]
    158
  • AHS temperate annual energy saved [kWh primary energy/y]
    1397
  • AHS cold annual energy saved [kWh primary energy/y]
    2732
  • AHS warm annual energy saved [kWh primary energy/y]
    632
  • Size A (mm)
    Ø 155
  • Size B (mm)
    110
  • Size C (mm)
    107
quota

Accessories

Discover accessories related to the product

C 1.5 (COMANDO EL. 1.5 A)
C 1.5 (COMANDO EL. 1.5 A)
Electronic speed controller. Maximum load: 1.5 A.
SCNRB I
SCNRB I
• Non-reversible electronic speed controller. • Built-in.
STAFFA SOTTOTETTO/SOFFITTO D.150
STAFFA SOTTOTETTO/SOFFITTO D.150
• Loft mounting brackets – Diam. 150/6”.
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info