Description

• Pickled and phosphated steel housing with polyester powder-coated finish, resistant to the aggressive action of atmospheric agents.
• Nominal diameter 150 mm.
• 3 speed fan consisting of:
• External rotor AC motor with thermal overload cutout and shaft turning in ball bearings,
• backward curved centrifugal impeller.
• Operation controllable by remote sensors monitoring: Temperature, Relative Humidity, Smoke and Presence.
• Zinc-coated steel brackets for wall mounting.
Read full descriptionClose description

Certifications

  • CE CE
    Download
  • EAC EAC
  • G-Mark G-Mark
  • UKCA UKCA
  • CB TEST CERTIFICATE CB TEST CERTIFICATE
ca_md_e_ambiente01

Technical Data Sheet

  • Frequency (Hz)
    50-60
  • Insulation class
    II°
  • IP
    44
  • Max absorbed current at maMinx speed at 60 Hz (A)
    0,38
  • Max absorbed current at Max speed (A)
    0,40
  • Max absorbed current at Max speed at 60 Hz (A)
    0,50
  • Max absorbed current at Mid speed (A)
    0,38
  • Max absorbed current at Mid speed at 60 Hz (A)
    0,45
  • Max absorbed current at Min speed (A)
    0,33
  • Max absorbed power at Max speed (W)
    68
  • Max absorbed power at Max speed at 60 Hz (W)
    80
  • Max absorbed power at Mid speed (W)
    50
  • Max absorbed power at Mid speed at 60 Hz (W)
    62
  • Max absorbed power at Min speed at 60 Hz (W)
    0,38
  • Max ambient temperature for continuous operation (°C)
    50
  • Nominal diameter (mm)
    150
  • Power absorbed at 1st speed (W)
    0,33
  • Voltage (V)
    220-240
  • Weight (Kg)
    4,9
  • Airflow at 1st speed (l/s)
    88
  • Airflow at 1st speed (m³/h)
    315
  • Breakout sound power at Max speed at 60 Hz LWA [dB (A)]
    58,6
  • Breakout sound power at Mid speed at 60 Hz LWA [dB (A)]
    54
  • Breakout sound power at Min speed at 60 Hz LWA [dB (A)]
    48,2
  • Breakout sound power LWA at Max speed [dB (A)]
    60,5
  • Breakout sound power LWA at Mid speed [dB (A)]
    55,2
  • Breakout sound power LWA at Min speed [dB (A)]
    46,7
  • breakout sound pressure at 3m at Max speed at 60 Hz Lp [dB (A)]
    38
  • Breakout sound pressure at 3m at Max speed Lp [dB (A)]
    39,9
  • breakout sound pressure at 3m at Mid speed at 60 Hz Lp [dB (A)]
    33,5
  • Breakout sound pressure at 3m at Mid speed Lp [dB (A)]
    34,7
  • breakout sound pressure at 3m at Min speed at 60 Hz Lp [dB (A)]
    27,7
  • Breakout sound pressure at 3m at Min speed Lp [dB (A)]
    26,2
  • Max airflow at Max speed (l/s)
    129
  • Max airflow at Max speed (m³/h)
    465
  • Max airflow at Max speed at 60 Hz (l/s)
    114
  • Max airflow at Max speed at 60 Hz (m³/h)
    410
  • Max airflow at Mid speed (m³/h)
    410
  • Max airflow at Mid speed at 60 Hz (l/s)
    108
  • Max airflow at Mid speed at 60 Hz (m³/h)
    390
  • Max airflow at Min speed (l/s)
    114
  • Max airflow at Min speed at 60 Hz (l/s)
    88
  • Max airflow at Min speed at 60 Hz (m³/h)
    315
  • Max pressure at 60 Hz (mmH2O)
    29,9
  • Max pressure at Max speed (mmH20)
    40,7
  • Max pressure at Max speed (Pa)
    399
  • Max pressure at Max speed at 60Hz (Pa)
    293
  • Max pressure at Mid speed (mmH2O)
    33,9
  • Max pressure at Mid speed (Pa)
    333
  • Max pressure at Mid speed at 60Hz (mmH2O)
    26,5
  • Max pressure at Mid speed at 60Hz (Pa)
    260
  • Max pressure at Min speed at 60Hz (mmH2O)
    23,8
  • Max pressure at Min speed at 60Hz (Pa)
    233
  • Max RPM
    2350
  • Max speed at 60 Hz (Rpm)
    2085
  • Mid speed at 60 Hz (Rpm)
    1965
  • Min RPM
    1480
  • Min speed at 60 Hz (Rpm)
    1530
  • Potenza sonora at supply side at Min speed LWA [dB (A)]
    73,3
  • Pressure at 1st speed (mmH20)
    25,6
  • Pressure at 1st speed (Pa)
    251
  • RPM at Mid speed
    2050
  • Sound power at extract side at Max speed LWA [dB (A)]
    89,1
  • Sound power at extract side at Mid speed LWA [dB (A)]
    84,2
  • Sound power at extract side at Min speed LWA [dB (A)]
    76,2
  • Sound power at supply side at Max speed LWA [dB (A)]
    86,3
  • Sound power at supply side at Mid speed LWA [dB (A)]
    81,5
  • Sound powerat at extraction side at Max speed at 60 Hz LWA [dB (A)]
    87,1
  • Sound powerat at extraction side at Mid speed at 60 Hz LWA [dB (A)]
    83,1
  • Sound powerat at extraction side at Min speed at 60 Hz LWA [dB (A)]
    76,6
  • Sound powerat at supply side at Max speed at 60 Hz LWA [dB (A)]
    84,4
  • Sound powerat at supply side at Mid speed at 60 Hz LWA [dB (A)]
    80
  • Sound powerat at supply side at Min speed at 60 Hz LWA [dB (A)]
    74,6
  • Sound pressure at extract side at 3m at Max speed at 60 HzLp [dB (A)]
    69,6
  • Sound pressure at extract side at 3m at Max speed Lp [dB (A)]
    71,6
  • Sound pressure at extract side at 3m at Mid speed at 60 HzLp [dB (A)]
    62,5
  • Sound pressure at extract side at 3m at Mid speed Lp [dB (A)]
    66,7
  • Sound pressure at extract side at 3m at Min speed at 60 HzLp [dB (A)]
    59,1
  • Sound pressure at extract side at 3m at Min speed Lp [dB (A)]
    58,7
  • Sound pressure at suply side at 3m at Max speed Lp [dB (A)]
    68,8
  • Sound pressure at suply side at 3m at Mid speed Lp [dB (A)]
    63,9
  • Sound pressure at suply side at 3m at Min speed Lp [dB (A)]
    55,8
  • Sound pressure at supply side at 3m at Max speed at 60 HzLp [dB (A)]
    66,8
  • Sound pressure at supply side at 3m at Mid speed at 60 HzLp [dB (A)]
    65,6
  • Sound pressure at supply side at 3m at Min speed at 60 HzLp [dB (A)]
    57,1


* Technical datas above refer to the product powered at 50 Hz.
For values for 60 Hz power supply, please contact the VORTICE Presales Service at prevendita@vortice-italy.com.

  • Type of heat recovery system HRS
    nessuno
  • Drive type
    a velocità multiple: VM
  • Declared type
    UVNR-U
  • Supplier's name or trade mark:
    Vortice
  • Supplier's name or trade mark
    Vortice
  • Declared type
    UVNR-U
  • Type of drive
    a velocità multiple: VM
  • Type of heat recovery system HRS
    nessuno
  • AEC annual electric energy consuption (kWh of primary energy/y)
    469,79
  • SFPint (W/m3/s)
    514,43
  • Heat recovery nominal efficiency (%)
    NA
  • Thermal efficiency of heat recovery (%)
    NA
  • Nominal NRVU airflow (m3/s)
    0,13908
  • ([m3/s)
    0,11429
  • Real absorbed electric power (KW)
    0,068
  • Effective electic power input [kW]
    0,071
  • Face velocity at nominal airflow (m/s)
    6,46727
  • Face velocity at nominal flowrate (m/s)
    17,70864
  • Nominal external pressure (Pa)
    11
  • Nominal external pressure (Pa)
    41
  • Inner pressure drop of ventilation components (Pa)
    264
  • Internal pressure drop of ventilation components (Pa)
    176
  • Internal pressure drop of non-ventilation components (Pa)
    0
  • Inner pressure drop of components not related to ventilation (Pa)
    0
  • Fan static efficiency according to 327/2011/UE regulation (%)
    51,3
  • Fan static efficiency according to Regulation (EU) No 327/2011 (%)
    36,6
  • Declared maximum internal leakage rate of the ventilation unit casing (%)
    NA
  • Declared maximum internal leakage rate of the ventilation unit casing (%)
    NA
  • Declared maximum external leakage rate of the ventilation unit casing (%)
    1,63
  • Declared maximum external leakage rate of the ventilation unit casing (%)
    NA
  • Filter energy performance or classification
    NA
  • Filter energy performance or classification
    NA
  • Description of visual filter warning
    NA
  • Description of visual filter warning:
    NA
  • Casing sound power level LWA [dB(A)]
    62
  • Casing sound power level (LWA) [dB(A)]
    60,5
  • Size A (mm)
    347
  • Size B (mm)
    275
  • Size C (mm)
    424
  • Size D (mm)
    147
  • Size E (mm)
    17
  • Size F (mm)
    17
quota
Curva_JPG_16163-Curve_per_Catalogo

Accessories

Discover accessories related to the product

CA-MU  (STAFFE DI SOSTEGNO)
CA-MU (STAFFE DI SOSTEGNO)
• Galvanized sheet-metal brackets for wall or ceiling mounting. Complete in packs of 2.
KIT SCB (TRASF.E.C.)
KIT SCB (TRASF.E.C.)
• Built-in controller adaptor.
CA-G 150 (GRIGLIA DI PROTEZIONE)
CA-G 150 (GRIGLIA DI PROTEZIONE)
Protection grille for use in the intake port when unit is mounted within reach.
C TEMP
C TEMP
Environmental sensor for temperature control.
C SMOKE
C SMOKE
Environmental sensor for air quality.
C HCS
C HCS
Environmental sensor for relative humidity control.
C PIR
C PIR
• Passive infrared sensor.
C TIMER
C TIMER
• Adjustable over-run timer.
TRIO D
TRIO D
3 speed dipswitch for installation in Standard DIN box.
TRIO-LINEO 503
TRIO-LINEO 503
Cookies help us to provide our services. By using these services, you accept our use of cookies. Info